DPDK PCI Allowlist Validation

The dpdk-validation role validates that the DPDK PCI devices declared by one-deploy match the effective Open vSwitch DPDK configuration on each hypervisor.

Enable the test

The test is disabled by default.

To enable it, modify inventory/reference/group_vars/all.yml

set the run_dpdk_pci_allowlist field to true

validation:
  run_dpdk_pci_allowlist: true

The validation can be run independently with:

ansible-playbook \
  -i <inventory> \
  playbooks/validation.yml \
  --tags dpdk_pci_allowlist

Source of truth

Expected DPDK PCI devices are derived directly from the deployment inventory. An interface is considered a DPDK interface when its ovs.iface configuration contains a type beginning with dpdk and an options:dpdk-devargs PCI address. For example:

ovs:
  iface:
    vmnic0:
      set:
        - type: dpdk
        - options:dpdk-devargs: '0000:19:00.0'

The expected PCI list is therefore not duplicated in the validation configuration.

Runtime validation

For every inventory-defined DPDK PCI device, the role validates:

  • The PCI address exists under /sys/bus/pci/devices.
  • The device is present in the Open vSwitch DPDK EAL allowlist configured through Open_vSwitch.other_config:dpdk-extra.
  • The device is present in an Open vSwitch interface whose type is dpdk.
  • No expected device is missing from the allowlist.
  • No unexpected device is present in the allowlist.
  • No expected device is missing from the runtime DPDK interfaces.
  • No unexpected runtime DPDK device is present.
  • No duplicate allowlist entries exist.
  • No duplicate runtime DPDK devices exist. The role records a per-host result using the key: DPDK PCI allowlist on

These node-host results are folded into the main validation report.

Persistence validation

The same validation is reusable after a host reboot. To validate persistence:

  1. Run the validation and confirm that it passes.
  2. Reboot the hypervisor.
  3. Wait for Open vSwitch and the host networking configuration to recover.
  4. Run the validation again. A successful post-reboot run verifies that the inventory-defined DPDK devices, the persisted OVS DPDK allowlist and the runtime DPDK interfaces remain consistent. Example DPDK allowlist For two DPDK interfaces:
ovs:
  set:
    - other_config:dpdk-init: 'true'
    - other_config:dpdk-extra: '-a 0000:19:00.0 -a 0000:5e:00.0'

The corresponding expected validation result contains:

expected:
  - 0000:19:00.0
  - 0000:5e:00.0

effective_allowlist:
  - 0000:19:00.0
  - 0000:5e:00.0

runtime_dpdk_devices:
  - 0000:19:00.0
  - 0000:5e:00.0

with all missing, unexpected, duplicate and missing-hardware lists empty.

Non-DPDK hosts

If the role is invoked on a host with no inventory-defined DPDK interfaces, the result is recorded as skipped. This allows the role to operate safely across a node group containing a mix of DPDK and non-DPDK hypervisors.