class OnboardTemp(object):
"""
Class or onboard temperature sensor
"""
def __init__(self, name=None, machine=None, ref_temp=None, bit_range=None, operating_voltage=None):
self.name = name
self.sensor = machine
self.ref_temp = ref_temp
self.bit_range = bit_range
self.operating_voltage = operating_voltage
self.maximum = 0.0
self.minimum = 0.0
self.current_temp = 0.0
self.previous_temp = 0.0
self.setup = True
self.reading_available = False
self.max_change = True
self.min_change = True
if self.operating_voltage and self.bit_range:
self.conversion_factor = self.operating_voltage / self.bit_range
def reset_reading(self):
self.reading_available = False
self.max_change = False
self.min_change = False
return
def get_reading(self, verbose=True):
msg_str = ""
reading = (self.sensor.read_u16()) * self.conversion_factor
self.current_temp = self.ref_temp - ( reading - 0.706)/0.001721
self.current_temp = round(self.current_temp,1)
if bool(self.setup):
msg_str = ("| ----- First run, initial max and min set.\n")
self.maximum = self.current_temp
self.minimum = self.current_temp
self.setup = False
else:
if self.current_temp != self.previous_temp:
self.reading_available = True
self.previous_temp = self.current_temp
if (self.current_temp > self.maximum):
self.maximum = self.current_temp
self.max_change = True
msg_str += ("| ----- Updating maximum: {}!!\n".format(self.maximum))
if (self.current_temp < self.minimum):
self.minimum = self.current_temp
self.min_change = True
msg_str += ("| ----- Updating minimum: {}!!\n".format(self.minimum))
if verbose and len(msg_str) >0:
print(msg_str)