Skip to content

FluxTubes.Basic.ElectroMagneticConverter: L_stat#4739

Merged
AHaumer merged 2 commits intomodelica:masterfrom
AHaumer:FT_EMconverter
Feb 16, 2026
Merged

FluxTubes.Basic.ElectroMagneticConverter: L_stat#4739
AHaumer merged 2 commits intomodelica:masterfrom
AHaumer:FT_EMconverter

Conversation

@AHaumer
Copy link
Contributor

@AHaumer AHaumer commented Feb 16, 2026

Both the ElectrocMagenticConverter and the ElectroMagneticConverterWithLeakageInductance lack a warning that L_stat is only valid if the coil is the only source in the magnetic circuit, Otherwise the magnetc flux is at least partly driven by other sources, too, and the calculation of L_stat is misleading.
Additonally, in the equation for L_stat the usage of noEvent has been corrected.

@AHaumer AHaumer added this to the maintenance milestone Feb 16, 2026
@AHaumer AHaumer self-assigned this Feb 16, 2026
@AHaumer AHaumer added bug Critical/severe issue L: Magnetic.FluxTubes Issue addresses Modelica.Magnetic.FluxTubes P: trivial Trivial issue labels Feb 16, 2026
@AHaumer AHaumer enabled auto-merge February 16, 2026 13:32
@AHaumer AHaumer added documentation Issue addresses the documentation and removed P: trivial Trivial issue labels Feb 16, 2026
@AHaumer AHaumer requested review from maltelenz February 16, 2026 17:26
Copy link
Contributor

@christiankral christiankral left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Important improvement

@AHaumer AHaumer merged commit 74c1caa into modelica:master Feb 16, 2026
11 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

bug Critical/severe issue documentation Issue addresses the documentation L: Magnetic.FluxTubes Issue addresses Modelica.Magnetic.FluxTubes

Projects

None yet

Development

Successfully merging this pull request may close these issues.

3 participants